I completed a diagnostic call on a Carrier air conditioner. I found that the return drop has fallen from 10’ ceiling joist, drawing basement air and interfering with duct balance. Adjusted cooling airflow from thermostat MAX to EFF. Customer will keep us updated to see if that helped with the noise.
I went to pinpoint a reason for water leaking from the ceiling.
I arrived to complete a diagnostic on an air conditioner. Upon inspection I determined that 3 of the 4 zones have gone bad as well as the thermostat. Provided the customer with recommendations. System is operational at time of departure.
I arrived to install a media cabinet for a Five Star air conditioner.
I completed a service call on a Five Star 13 SEER 2 Ton Air Conditioner. 4” cabinet needs installed due to static being to high.
I completed a diagnostic on a Trane Air conditioner. I determined that the drain pan switch was bad, I replaced the switch and checked the charge on the unit. System was operational at time of departure.
I completed a diagnostic on a Carrier furnace. Found unit was leaking. Fixed the leak with a water switch and rerunning drain line.
I completed a diagnostic service call on an air conditioner, I determined that the unit was in need of a new compressor. I went over options with the customer.
I completed a return service to rewire the thermostat to the Rheem gas furnace. I determined that the Ecobee thermostat was faulty as the unit was not communicating properly to the air conditioner. I went over options with the customer.
I completed a diagnostic Rheem air conditioner. I determined that the unit's wiring needed to be corrected. Went over options with the customer.
Client requested an estimate to replace an air conditioner. I recommend replacing it with a Carrier 13 SEER 2 Ton Air Conditioner. Included in the estimate is a 1 year free service maintenance agreement.
I completed a diagnostic service call on an air conditioner. I determined that the leak has grown and that the unit may need replaced. I went over options with the customer.
I completed a diagnostic service call on an air conditioner. I determined that the leak has grown. I went over options with the customer.
I completed a diagnostic service call on an American Standard air conditioner. I determined that the blower needed to be adjusted. System was operational upon departure.
I completed a return service call on an ICP gas furnace to the indoor air handler coil. Will be ordering part to replace and scheduling with the customer.